Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - ROUGH, SOIL
Permit Number - T11CM01012
Inspection Description - PLUMBING - ROUGH, SOIL
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
06/07/2011 | PLUMBING - ROUGH, SOIL | Approved | IVRS - Inspection :* | |
06/02/2011 | PLUMBING - ROUGH, SOIL | Not ready for Inspection | IVRS - Inspection :* 1) NOT INSTALLED PER PLAN AND NO RED LINES ON SITE 2) HORIZONTAL X HORIZONTAL CHANGE OF DIRECTION TO BE A SWEEP 3) VERTICAL AND HORIZONTAL CHANGE OF DIRECTION TO BE A SWEEP 4) HORIZONTAL VENTING BELOW THE FLOOD RIM TO BE LIMITED TO STRUCTURAL CONDITION 5) ALL PIPING TO BE SLOPED AT 2 PERCENT |