Permit: T11CM00955

Parcel: 140552370

Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Date Description Inspector Results Comments
11/30/2011 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection :*
11/29/2011 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) ABS NEEDS TO BE TO PLANS AND CODE
2) NAIL OFF SHEAR TRUSS PER 204
3) NAIL OFF SHEATHING
4) NAIL OFF DBL STUDS FOR HOLDOWNS THRU SHATHING
5) NAIL OFF TRIMMERS AT GARAGE
6) NAIL OFF TOP OF SHEATHING EAST SIDE
7) NAIL OFF ROOF PER 201 DETAIL AT BIRD BOARDS
11/02/2011 EXT METAL CLIPS/EXT SHEATHING Not ready for Inspection IVRS - Inspection :*