Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - INTERMEDIATE
Permit Number - T11CM00943
Inspection Description - PLUMBING - INTERMEDIATE
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
06/01/2011 | PLUMBING - INTERMEDIATE | Approved | IVRS - Inspection :* | |
05/31/2011 | PLUMBING - INTERMEDIATE | Denied | IVRS - Inspection : See detailed listing on site.| 999* CODES DO NOT ALLOW THIS INSTALLATION. A VENT PIPE MAY NOT BE USED A AS WASTE PIPE. 311.4 ALSO RUBBER COUPLINGS AND FITTINGS AR NOT APPROVED |
|
05/20/2011 | PLUMBING - INTERMEDIATE | Not ready for Inspection | IVRS - Inspection :* 1) 1 1/2" TRAP ARM MAY ONLY EXTEND 3' 6" FROM THE TRAP WEIR TO THE POINT OF VENT 2) 1 1/2" GALVANIZED 90 DEGREE ELBOW IS NOT A DRAINAGE FITTING 3) 1 1/2" TRAP ARM TO MAINTAIN 1/4" PER FOOT PITCH |