Permit: T11CM00891

Parcel: 130080590


Addresses:

3757 E 27TH PL

Inspection Status: Approved

Inspection History: MECHANICAL - FINAL

Date Description Inspector Results Comments
08/29/2011 MECHANICAL - FINAL Approved IVRS - Inspection :*
08/22/2011 MECHANICAL - FINAL Partial Approval PROVIDE THE BUSHING IN DISCONNECT. TAPE WHITE WIRES WITH BLACK TAPE
PROVIDE A ROOF JACK AT CONDESATE PENETRATION
08/03/2011 MECHANICAL - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) PROVIDE A BUSHING IN ELECTRIC DISCONNECT WHERE CONDUCTORS ENTER A/C UNIT
2) BLOCK AND CLAMP PVC EVERY 4', TERMINATE WITHIN 6" OF THE GROUND AND PAINT EXPOSED PVC WITH LATEX PAINT
3) CONDENSATE MUST TERMINATE ONTO DIRT
4) LABEL CIRCUIT BREAKER FOR A/C