Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 05/23/2011 | FRAMING | Approved | IVRS - Inspection :* | |
| 05/20/2011 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) FIRE FOAM OPENINGS WHERE NEEDED 2) BANG WIRES AT N.W. KIT. CORNER 3) REMOVE MESH STAPLES BEHIND HOME RUNS 4) SHIM HEADER AT WEST PATIO DOOR 5) REPAIR TOP PLATES AT STOVE VENT |