Inspection History Details
Inspection Status: Approved
Inspection History: ELECTRIC - INTERMEDIATE
Permit Number - T11CM00845
Inspection Description - ELECTRIC - INTERMEDIATE
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
09/13/2012 | ELECTRIC - INTERMEDIATE | Approved | ||
08/07/2012 | ELECTRIC - INTERMEDIATE | Partial Approval | BATHROOMS | |
08/02/2012 | ELECTRIC - INTERMEDIATE | Partial Approval | SOFFITS OK, NORTH SIDE HARD LIDS OK | |
07/31/2012 | ELECTRIC - INTERMEDIATE | Partial Approval | STORE FRONT | |
07/24/2012 | ELECTRIC - INTERMEDIATE | Partial Approval | IVRS - Inspection :* | |
07/19/2012 | ELECTRIC - INTERMEDIATE | Partial Approval | IVRS - Inspection :* ZONE 2 |
|
05/31/2012 | ELECTRIC - INTERMEDIATE | Partial Approval | IVRS - Inspection :* 1) LABEL PANEL DIRECTORIES PER 408.4 2) PROTECT CONDUCTOR ?00.4 3) USE APPROVED HARDWARE FOR PANEL MOUNTING 4) PROPERLY SUPPORT EMT AND NO MORE THAN 360 DEGREE IN A RUN 5) OK PANELS HA, 1LA, 2LA, 3LA,LB1,LB2 AND HB, EXCEPT AS NOTED 6) FOR AREA INSPECTIONS HAVE 2 FLOOR BOXES OPEN, 2 TRAC LINE ENDS OPEN, LVD POWER SUPPLY OPEN, 2 FLOURESCENTS OPEN, CHECK RECEPTS AND EM LIGHTING 7) 366.22 WILL APPLY 8) LOCK NUTS BACKWARDS 9) A/C TO TERMINATE |
|
05/17/2012 | ELECTRIC - INTERMEDIATE | Denied | IVRS - Inspection : See detailed listing on site.| 999* |
|
05/07/2012 | ELECTRIC - INTERMEDIATE | Partial Approval | IVRS - Inspection :* 1) JUNCTION BOXES TO BE ACCESSIBLE 2) OK BOTTOM ESCALATORS 1ST FLOOR 3) OK LAST SECTIONS AROUND ESCALATORS |
|
04/17/2012 | ELECTRIC - INTERMEDIATE | Partial Approval | IVRS - Inspection :* | |
04/11/2012 | ELECTRIC - INTERMEDIATE | Partial Approval | IVRS - Inspection :* 1) OK CENTER AT SKY LIGHT, ESCALATOR, CANS AND 3 BOXES |
|
04/09/2012 | ELECTRIC - INTERMEDIATE | Partial Approval | IVRS - Inspection :* 1) NEED ACCESS FOR MOTOR AND SIGN EQUIPMENT 2) OK SOUTH LIGHT BOX |
|
04/02/2012 | ELECTRIC - INTERMEDIATE | Partial Approval | IVRS - Inspection :* OK CANS + SUPPORTS HANGING HARD LID LEVEL #1 EXCEPT CENTER SECTIONS |
|
03/30/2012 | ELECTRIC - INTERMEDIATE | Denied | IVRS - Inspection : The wiring is not complete or does not comply with code.| 245* 1) SUPPORT WIRES NEED TO BE TIED AT BOTH ENDS 300.11 NEC |
|
03/28/2012 | ELECTRIC - INTERMEDIATE | Partial Approval | IVRS - Inspection :* 1) SUPPORT M/C CABLE 330.30 & 300.11 2) SUPPORT OR REMOVE VDV CABLING 725.3 & 8, 800.3 & 24 AND 300.11 3) FINISH SOUTH SOFFITS 4) OK SOUTH CASH WRAP WALLS 5) OK SOFFITS EXCEPT AS NOTED AFTER CORRECTION |
|
03/16/2012 | ELECTRIC - INTERMEDIATE | Partial Approval | IVRS - Inspection :* 1) OK FLOOR BOXES, EXCEPT AT ESCALATOR 2) OK COLUMN RECEPTS AND PERIMETER WALLS, EXCEPT AS NOTED 3) PROTECT PVC AT BASE PLANCES 4) FINISH LIGHT BOXES AND CONDUIT RUNS CASH WRAPS 5) INSTALL VDV CABLING |