Permit: T11CM00789

Parcel: 13510150R

Inspection Status: Approved

Inspection History: ELECTRIC - ABOVE CEILING

Permit Number - T11CM00789

Inspection Description - ELECTRIC - ABOVE CEILING

Inspection Status - Approved

Date Description Inspector Results Comments
06/29/2011 ELECTRIC - ABOVE CEILING Approved IVRS - Inspection :*
06/21/2011 ELECTRIC - ABOVE CEILING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) LOW VOLTAGE PIPES MISSING PLASTIC BUSHING 110.14A
2) OUTLET IN BATHROOM TO BE GFI 210.8-B1
3) J-BOX IN BATHROOM HAS ROMEX WIRE NOT TO BE USED IN TEE-BAR CEILING 334.12-A2
4) OUTLET QUAD IN BATHROOM MISSING SCREWS 406.4-C
5) EXIT NOT WORKING PROPERLY WHEN POWER SHUT OFF 700.17