Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
Permit Number - T11CM00709
Inspection Description - FRAMING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
05/17/2011 | FRAMING | Approved | IVRS - Inspection :* | |
05/16/2011 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) FILL ALL HOLES IN FHA PANEL AT TOP PLATE IN KITCHEN 2) NAIL FLOOR TRUSS LATTERAL BRACE TO END WALLS 3) IS SOLAR WATER HEATER GLYCOL LINE 1/2" LARGE ENOUGH 4) FINISH NAILING OFF #3 SHEAR MAIN FLOOR STAIRWAY 5) BLOCK DUCT MINIMUM 3 SIDES IN BATH UNDER STAIRS |