Permit: T11CM00683

Parcel: 128141220


Addresses:

914 S MAGNOLIA AV

Inspection Status: Approved

Inspection History: PLUMBING - GAS PRESS TEST FNL

Date Description Inspector Results Comments
08/16/2011 PLUMBING - GAS PRESS TEST FNL Approved IVRS - Inspection :*
06/27/2011 PLUMBING - GAS PRESS TEST FNL Partial Approval IVRS - Inspection :*
1) PROVIDE 1" CLEARANCE B-VENT FROM COMBUSTIBLES
2) PRESSURE TEST OK 10 POUNDS
05/09/2011 PLUMBING - GAS PRESS TEST FNL Not ready for Inspection GAS NOTES FROM INSPECTION BY BOB RICH 5/26/2010 ON ACTIVITY T10PL00818
IVRS - Inspection :*
1) SOUTH FURNACE: PROVIDE 4" DBL WALL VENT THRU ROOF TO 3' ABOVE TOP OF COOLER INTAKE WITH 4" APPROVED VENT CAP
2) CAP OLD GAS PIPING INSIDE BLDG
3) PROVIDE BONDING OF BLDG GAS SYSTEM
4) PROVIDE RIDGID PIPE FOR TEMPERATURE AND PRESSURE RELIEF DRAIN WITH 1" AIR GAP AND TIGHTEN UNION (NO FLEX FOR WATER HEATER AND T & P DRAIN)
5) SEAL 2" PIPE PENETRATION INTO EXTERIOR SOFFIT (FOR BUG PROOF)
6) SEAL ROOF FLASHING TO DBL WALL VENTING WEATHER TIGHT
7) CLAMP 2" PIPE TO BLOCK ON ROOF AND SECURE ALL PIPING IN ATTIC