Permit: T11CM00660

Parcel: 140122160


Addresses:

4951 S CAMPBELL AV

Inspection Status: Approved

Inspection History: PLUMBING - ROUGH, SOIL

Date Description Inspector Results Comments
09/20/2011 PLUMBING - ROUGH, SOIL Approved IVRS - Inspection :*
09/06/2011 PLUMBING - ROUGH, SOIL Partial Approval IVRS - Inspection :*
1) ABS DWV UNDERFLOOR FOR HAND SINK AND FLOOR SINK OK TO COVER
08/31/2011 PLUMBING - ROUGH, SOIL Not ready for Inspection IVRS - Inspection :*
08/30/2011 PLUMBING - ROUGH, SOIL Cancelled CANCELLED PER CONTRACTOR J.T. #480-772-3174
08/30/2011 PLUMBING - ROUGH, SOIL Not ready for Inspection IVRS - Inspection :*
1) CANCELLED
08/11/2011 PLUMBING - ROUGH, SOIL Partial Approval IVRS - Inspection :*
1) PLAN REQUIRES 3" GREASE WASTE, EXISTING ? IS 2" MAY NOT REDUCE DRAIN SIZE AT G.T.
2) EACH FIXTURE WILL REQUIRE A FLOW CONTROL, FLOW CONTROL MUST BE IN READILY ACCESSIBLE AND VISIBLE LOCATION
3) RECOMMEND A "ROCKFORD" GREASE TRAP WITH INTEGRAL FLOW CONTROL
08/04/2011 PLUMBING - ROUGH, SOIL Partial Approval IVRS - Inspection :*
CHANGE TO CLOSET LOCATION OK
07/28/2011 PLUMBING - ROUGH, SOIL Partial Approval IVRS - Inspection :*
1) WATER TEST PER INITIALS PAGE MEP 3.0 WITH REVENT AND VENT TO POINT OF CONNECTION
2) PIPE WRAPS AND TRAP PRIMER
3) NEED TO SEE STOOL MOVE AND GREASE WASTE & INTERCEPTOR
07/27/2011 PLUMBING - ROUGH, SOIL Not ready for Inspection IVRS - Inspection :*
1) CONSULTATION ONLY, PROBLEM WITH GREASE INTERCEPTOR NOT GRAVITY DRAIN, NO FLOW CONTROL, ADDITION OF FLOOR SINK WOULD REQUIRE INTERCEPTOR GRAVITY TYPE, OR INTERVAL FLOW CONTROL TYPE