Inspection Status: Approved
Inspection History: MECHANICAL - FINAL
Permit Number - T11CM00632
Inspection Description - MECHANICAL - FINAL
Inspection Status - Approved
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 04/06/2012 | MECHANICAL - FINAL | Approved | IVRS - Inspection :* | |
| 03/16/2011 | MECHANICAL - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) PROVIDE THE PROPER STRUCTURAL DRAWING FOR NEW A/C UNIT ON THE ROOF. THE DRAWING PROVIDED HAS NO INFORMATION 2) SLEEPERS MUST SPAN THE ROOF JOINTS 3) PAINT ALL EXPOSED PVC WITH LATEX PAINT AND SUPPORT EVERY 4' 4) PROVIDE MINIMUM 2" R8 DUCT LINER IN ALL EXPOSED DUCT ON ROOF |