Permit: T11CM00606

Parcel: 140264780

Inspection Status: Approved

Inspection History: FRAMING

Permit Number - T11CM00606

Inspection Description - FRAMING

Inspection Status - Approved

Date Description Inspector Results Comments
03/25/2011 FRAMING Approved IVRS - Inspection :*
03/24/2011 FRAMING Partial Approval IVRS - Inspection :*
03/22/2011 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) BLOCK REGISTER BOOTS 3 SIDES
2) SECURE ALL ROMEX 8" FROM BOXES
3) PROVIDE NAILERS AT CEILING HEIGHT EAST WALL
4) SECURE BASE PLATES MASTTER CLOSET
5) RED HEAD 1/2" AB AT PLATE JOINTS
6) MISSING 110 GFCI SERVICE OUTLET AT NEW CONDENSOR LOCATION
7) CHANGE TO BEDROOM CLOSET DOOR SIZE HEADER OVERSPANNED CRIPPLES OVERSPANNED