Permit: T11CM00460

Parcel: 141311960

Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Permit Number - T11CM00460

Inspection Description - EXT METAL CLIPS/EXT SHEATHING

Inspection Status - Approved

Date Description Inspector Results Comments
03/23/2011 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection :*
03/21/2011 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) NAILS MISSING IN RSP4 EAST SIDE
2) NAIL PROTECT PLUMBING WITHIN 1 1/4" BOTTOM PLATE
3) NAIL OF A35 AT BIRD BOARDS AND TOP PLATES