Permit: T11CM00419

Parcel: 13813001B


Addresses:

5701 S 12TH AV


Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Permit Number - T11CM00419

Inspection Description - PLUMBING - FINAL

Inspection Status - Approved

Date Description Inspector Results Comments
10/04/2011 PLUMBING - FINAL Approved PER INSP CARD
09/08/2011 PLUMBING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) ABS AND PVC ARE NOT PERMITTED TO BE INSTALLED IN EXPOSED EXTERIOR LOCATIONS
2) HOW IS THE WATER SUPPLY TO THE DISPENSOR PROTECTED ?
3) ARMAFLEX INSULATION DETERIORATED IN U.V. LOCATIONS, USE ROOFING MASTIC (WHITE) TO WEATHER PROOF INSULATION
4) PROVIDE LISTING FOR AAV TO BE INSTALLED IN EXPOSED EXTERIOR LOCATION
08/24/2011 PLUMBING - FINAL Partial Approval IVRS - Inspection :*
WAITING ON DATER DISPENSOR INSTALL ONLY
08/22/2011 PLUMBING - FINAL Not ready for Inspection PROVIDE BACTERIA REPORT, STERILIZATION REPORT ON SITE.
PROVIDE LONG RADIUS 90 DEG AT SINK AT VACUUM STATION WITH PLASTIC MALG ADAPTER. ALL (1) TYPE MATERIAL. INSULATE HOSE BIB EXPOSED TO GREEZING.
PROVIDE ALL PVC AT AIR ADMITTANCE VALVE AT WATER STATION. COMPLETE WATER STATION INSTALLATION
08/16/2011 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*