Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit: T11CM00396

Parcel: 13505149X

Inspection Status: Approved

Inspection History: REINFORCED MASONRY PRE-GROUT

Permit Number - T11CM00396

Inspection Description - REINFORCED MASONRY PRE-GROUT

Inspection Status - Approved

Date Description Inspector Results Comments
01/12/2012 REINFORCED MASONRY PRE-GROUT Approved IVRS - Inspection :*
10/12/2011 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
1) 10 LIGHT POLE CAISSON FOOTINGS AS PER DETAILS #A-9, H-13; PAGE S530-OK TO POUR PROGRESS AREAS
10/11/2011 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
1) TRASH ENCLOSURE-TOPPED OUT, OK TO GROUT & CAP
09/27/2011 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
1) CORNER WALLS AT H/4, H/5-TOPPED OUT AT 20' 8" OK TO GROUT
09/26/2011 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
1) CMU CORNER WALLS AT GL: H/4, H/5 AT 5'-12' OK TO GROUT WITH CLEANOUTS
09/23/2011 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
MASONRY PRE-GROUT - PARTIAL: CMU TIE-IN WALL AT GL, H-5, H-4 AT 56" *
*RFI DATED 09-22-11 - OK TO GROUT PROGRESS AREAS TO BE GROUTED AT 8' LIFTS/WITH CLEAN-OUTS AS PER RFI.
09/22/2011 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
1) GL: H/4-5 APPROX 19' 6" AT 0"-48" GROUTED,
AWAITING RFI FROM ENGINEER-APPROVING PROPOSED WALL-TIE IN TO ADJACENT TO CMU COLUMNS AT GL H/4 & H/5
09/21/2011 REINFORCED MASONRY PRE-GROUT Not ready for Inspection IVRS - Inspection :*
1) CONTRACTOR CANCELLED
09/20/2011 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
1) 2 COLUMNS AT GL: C EAST & WEST TOPPED OUT AT 17' 4" OK TO GROUT
09/19/2011 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
1) 2 COLUMNS AT 12' GL: .5/C, 8.5/C OK TO GROUT COLUMNS
09/16/2011 REINFORCED MASONRY PRE-GROUT Not ready for Inspection IVRS - Inspection :*
09/15/2011 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
1) SOUTH SIDE COLUMNS TO 16' WALLS TOP OUT
09/14/2011 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
1) EAST,WEST AND NORTH WALLS TOP OUT WITH COMPLIANT SPECIAL INSPECTION
09/12/2011 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
1) 3RD LIFT OF MASONRY CMU AT STORE EXTERIOR WALLS FROM 8' TO 12' AFFE
09/08/2011 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
1) 2ND LIFT STORE EXTERIOR MASONRY WALLS FROM 4' TO 8' AFFE
2) SPECIAL INSPECTION BY SPEEDIE
09/06/2011 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
1) 1ST STORE EXTERIOR MASONRY WALLS-LIFT FROM 0' TO 4' AFFE-OK SPECIAL INSPECTION BY SPEEDIE
08/09/2011 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
1) STORE BLDG STEM WALL OK
2) SPEEDIE SPECIAL INSPECTION