Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - FINAL
Permit Number - T11CM00380
Inspection Description - PLUMBING - FINAL
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
06/15/2011 | PLUMBING - FINAL | Approved | IVRS - Inspection :* | |
06/10/2011 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :* 1) INDIRECT WASTE PIPING BETWEEN FIVE AND FIFTEEN FEET IN LENGTH SHALL BE DIRECTLY TRAPPED 2) ALL PVC JOINTS SHALL SHOW EVIDENCE OF PRIMER AS WELL AS SOVLANT CEMENT 3) IN PIPING TO BE OF APPROVED MATERIALS 4) LABEL BACKFLOW DEVICES 5) ALL EQUIPMENT TO BE HOOKED UP 6) FINISH INSULATION WATER PIPING 7) LABEL ANSUL VALVE 8) SEE NOTES FROM 06/09/11 |
|
06/09/2011 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :* 1) PARTIAL INSPECTION ONLY 2) LIST MAY NOT BE COMPLETE 3) NEED CORRECTIONS ON IN DIRECT WASTE PIPING: SLOPE, SUPPORTS, PROPER SOLVENTWELD JOINTS 4) SEPERATE DRAINS 5) NOTE: SOME EQUIPMENT IS NOT CONNECTED AT BACKFLOW PENETRATIONS 6) LABEL BACKFLOW VALVES, AND ID ON CERT 7) PROVIDE A DOCUMENTED PROCEDURE FOR STERLIZATION |