Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit: T11CM00345

Parcel: 138070690


Addresses:

802 W MOSSMAN ST

Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Date Description Inspector Results Comments
03/16/2011 PLUMBING - FINAL Approved IVRS - Inspection :*
03/15/2011 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
03/03/2011 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
02/24/2011 PLUMBING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) MIXED BREAKER TYPE IN PANEL/SINGLE NEUTRAL WIRE PER LUG. PROVIDE SECONDARY GROUND ROD WITH CONTINOUS #4/EXTERIOR CONDUIT FITTINGS NOT WEATHERED TYPE. SECURE #4 TO BLDG
2) SECURE EXT. GAS LINE PER CODE. WATER HEATER FLUE MISSING B-VENT. FLEX MAY NOT PENETRATE CABINET. TPR LINE MUST BE 3/4" COPPER OR CVPC. EXPOSE SUPPLY LINE SHUT OFF VALVE
3) HAZARDOUS 220 ELECTRICAL EXTERIOR
4) OMIT ELECTRICAL AT ENTRY PORCH
BEDROOM AND BATH:
1) WINDOW EGRESS SILL HEIGHT MAY NOT EXCEED 4"
2) PROVIDE LETTER HEAD FROM LICENSED ELECTRICIAN STATING ALL WORK DONE WITHOUT INSPECTIONS IS TO VODE FOR SAFETY
3) EXPOSE FOOTERS
4) EXPOSE ALL WALL TO BEAM CONNECTIONS FOR INSPECTION AT KITCHEN/DINING
5) PROVIDE ACCESS TO ATTIC IN BEDROOM