Permit: T11CM00330

Parcel: 121016460


Addresses:

1951 N WILMOT RD 01

Inspection Status: Approved

Inspection History: PLUMBING - ROUGH, SOIL

Date Description Inspector Results Comments
03/24/2011 PLUMBING - ROUGH, SOIL Approved IVRS - Inspection :*
03/14/2011 PLUMBING - ROUGH, SOIL Not ready for Inspection 1. POST SUITE NUMBER ON SITE. PROVIDE TEST ON ALL PIPING. INSTALL PER APPROVED PLAN AND 2006 UPC REQUIREMENTS. DRAIN ARMS CANNOT CHANGE ELEVATIONS. A VENT CANNOT BE USED AS A DRAIN. NOTE: TWO INCH TRAP ARMS REQUIRE TWO INCH P TRAPS. INCH AND A QUARTER TAILPIECES CAN ONLY HAVE INCH AND A HALF P TRAPS. ALL PIPING TO BE SUPPORTED AT CORRECT INTERVALS WITH APPROVED MEANS. LIST MAY NOT BE COMPLETE.