Permit: T11CM00240

Parcel: 114540640

Inspection Status: Approved

Inspection History: PLUMBING - ABOVE CEILING

Date Description Inspector Results Comments
02/17/2011 PLUMBING - ABOVE CEILING Approved IVRS - Inspection :*
1) TRAP AND TRAP ARM SHALL BE THE SAME SIZE
2) SWEEP REQUIRED ON HORIZONTAL CHANGE OF DIRECTION
3) 1/4" PER FOOT SLOPE MINIMUM ON WASTE AND MAX ON TRAP ARM
02/10/2011 PLUMBING - ABOVE CEILING Not ready for Inspection 1. INSTALL SAFETY PLATES. SEAL PIPE INSULATION WITH ADHESIVE PER INSTALLATION INSRUCTIONS. SUPPORT THE PIPE NOT THE FITTINGS. SUPPORT PEX AT MAX. 32'. ISOLATE.
02/09/2011 PLUMBING - ABOVE CEILING Not ready for Inspection IVRS - Inspection :*
02/08/2011 PLUMBING - ABOVE CEILING Not ready for Inspection IVRS - Inspection :*