Permit: T11CM00222

Parcel: 113011040


Addresses:

3605 N VINE AV

Inspection Status: Approved

Inspection History: MECHANICAL - FINAL

Date Description Inspector Results Comments
04/20/2011 MECHANICAL - FINAL Approved IVRS - Inspection :*
04/19/2011 MECHANICAL - FINAL Not ready for Inspection IVRS - Inspection :*
03/30/2011 MECHANICAL - FINAL Partial Approval IVRS - Inspection :*
1) PROVIDE A ROOF JACK AT ELECTRIC CONDUIT THRU ROOF
2) EXTEND PVC DRAIN TO WITHIN 6" OF THE GROUND
3) SUPPORT MAX 4' AND USE REDWOOD OR PRESSURE TREATED
4) MARK THE UNIT DATA PLATE WHETHER THERE IS A HEAT STRIP OR NOT
5) SOME SECTIONS OF KD DUCT NOT SNAPPED TOGETHER AND CRIMPED END NOT INSTALLED INTO ELBOW PROPERLY