Permit: T11CM00219

Parcel: 11308208F


Addresses:

2802 N 1ST AV


Inspection Status: Approved

Inspection History: PLUMBING - INTERMEDIATE

Permit Number - T11CM00219

Inspection Description - PLUMBING - INTERMEDIATE

Inspection Status - Approved

Date Description Inspector Results Comments
03/30/2012 PLUMBING - INTERMEDIATE Approved IVRS - Inspection :*
02/15/2012 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*
1) OK TO COVER WALLS S.T.O.I.
02/14/2012 PLUMBING - INTERMEDIATE Not ready for Inspection IVRS - Inspection :*
1) PROVIDE PLAN SPECS
02/10/2012 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*
1) WRAP PVC THRU CONCRETE
2) SUPPORT ALL VERTICAL PIPING. PVC TO BE SUPPORTED AT EACH CHANGE OF DIRECTION OR ELEVATION, AND AT THE END OF BRANCHES, THEN NO MORE THAN 4 FEET BETWEEN HANGERS
3) OK TO INSULATE PER PLAN
4) SEE DETAIL F8 P510 AND F12 P510