Inspection History Details
Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 02/25/2011 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection :* | |
| 02/23/2011 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) NAIL PROTECT CONDENSOR 220 GARAGE TOP PLATES-MISSING 2) MISSING SOLAR AT WATER PREPERATIONS 3) BLOCK REGISTER BOOTS 3 SIDES 4) 2 EACH 1/2" AB'S PER BRACED PANEL 5) PER DETAIL 1/S2 1/2" AB 48" CC ALL EXTERIOR WALLS. SUBMIT AS BUILT FOR OPTION MAS STRAPS 6) MISSING AB'S AT BEDROOM 4 BRACED PANEL 7) DAMAGED FIRE BLOCK KITCHEN WALL AT EXHAUST 8) INSULATE "Y" FITTINGS 9) PROVIDE STEP LADDER FOR VERIFICATION OF R VALVE FLEX |
|
| 02/17/2011 | EXT METAL CLIPS/EXT SHEATHING | Partial Approval | IVRS - Inspection :* 1) 2-ABS 1/2" PER BRACED PANEL |