Inspection Status: Approved
Inspection History: MECHANICAL - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 02/03/2011 | MECHANICAL - FINAL | Approved | IVRS - Inspection :* | |
| 02/01/2011 | MECHANICAL - FINAL | Partial Approval | IVRS - Inspection :* 1. PROVIDE GASKET BETWEEN RETURN AND MECH.ROOM 2.INSULATE SUPPY DUCT IN MECH ROOM |
|
| 01/28/2011 | MECHANICAL - FINAL | Partial Approval | IVRS - Inspection :* 1) T & P RELIEF VALVE CANNOT RUN UP HILL TO THE ROOF. USE ALTERNATE METHOD IF NECESSARY 2) PROVIDE A SHUT OFF VALVE IN THE WATER SUPPLY AT THE WATER HEATER 3) TERMINATE SINGLE WALL INTO EXISTING DBL WALL 4) GAS FLEX CANNOT PASS THRU THE CABINET OF THE FURNACE 5) DO NOT USE TAPE ON VENT CONNECTOR 6) LEFT PETITION OF APPEAL ON JOB SITE |