Inspection History Details
Inspection Status: Approved
Inspection History: MECHANICAL - FINAL
Permit Number - T11CM00186
Inspection Description - MECHANICAL - FINAL
Inspection Status - Approved
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 03/24/2011 | MECHANICAL - FINAL | Approved | IVRS - Inspection :* | |
| 03/22/2011 | MECHANICAL - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* |
|
| 03/16/2011 | MECHANICAL - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* |
|
| 03/01/2011 | MECHANICAL - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) THE A/C SYSTEM WAS INSTALLED WITHOUT PERMITS OR INSPECTIONS 2) RE-INSTALL ELECTRIC DISCONNECT 3) PROVIDE A FRESH AIR INTAKE 4) DO NOT HAVE SECONDARY DRAIN TERMINATED INTO PRIMARY DRAIN PIPE. YOU CAN USE AN OVERFLOW SENSOR FOR SECONDARY DRAIN |