Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - ROUGH, SOIL
Permit Number - T11CM00164
Inspection Description - PLUMBING - ROUGH, SOIL
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
02/21/2013 | PLUMBING - ROUGH, SOIL | Approved | ||
02/14/2013 | PLUMBING - ROUGH, SOIL | Not ready for Inspection | IVRS - Inspection :* | |
02/06/2013 | PLUMBING - ROUGH, SOIL | Not ready for Inspection | 1. Have licensed plumber on site at the time of the next inspection- Installation does not meet minimum requirements of any approved code. | |
02/01/2013 | PLUMBING - ROUGH, SOIL | Not ready for Inspection | 1. IPC/IRC does not recognize horizontal dry vents. "S" traps not permitted. Vents connecting to a horizontal drain to be taken off above the drainage center line. 4" sewer requires a 4" cleanout. Backpitched sections not approved. |