Permit: T11CM00163

Parcel: 13413057N

Inspection Status: Approved

Inspection History: PLUMBING - INTERMEDIATE

Permit Number - T11CM00163

Inspection Description - PLUMBING - INTERMEDIATE

Inspection Status - Approved

Date Description Inspector Results Comments
07/14/2011 PLUMBING - INTERMEDIATE Approved IVRS - Inspection :*
06/23/2011 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*
06/22/2011 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*
1) PROVIDE CORRECT DRAINAGE FOR DRINKING FOUNTAIN WITH TEST. THERE CAN BE NO CHANGE OF ELEVATION ON A DRAIN ARM
06/21/2011 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*
1) RESTROOM 2111 OK
2) CENTER OF DINING REROUTE OK
3) 2109 P.7 AND P.5 VENT CANNOT BE USED AS DRAIN, TRAP ARM CANNOT CHANGE ELEVATION
4) 2107 B+ P1.A VENT CANNOT BE USED A DRAIN, P.3 PROVIDE LONG RADIUS 90 DEGREE FOR TRAP ARM