Permit: T11CM00151

Parcel: 11205061A


Addresses:

1922 E HEDRICK DR

Inspection Status: Approved

Inspection History: PLUMBING - INTERMEDIATE

Date Description Inspector Results Comments
05/12/2011 PLUMBING - INTERMEDIATE Approved IVRS - Inspection :*
1) CORRECTIONS FROM 5/5/11 MADE OK
2) DON'T FORGET AT SINK: TRAP AND TRAP ARM TO BE THE SAME SIZE
3) CLOSET FLANGE OK
4) OK TO COVER WALLS S.T.O.I.
05/06/2011 PLUMBING - INTERMEDIATE Not ready for Inspection IVRS - Inspection :*
05/05/2011 PLUMBING - INTERMEDIATE Not ready for Inspection IVRS - Inspection :*
1) ISOLATE ABS FROM METAL STUDS
2) SUPPORT PIPING PER TABLE 3-2 2006 UPC
3) PLAN CALLS FOR TYPE "L" COPPER
4) MINIMUM WASTE SIZE FOR A SINK IS 2"
5) HORIZONTAL X HORIZONTAL CHANGE OF DIRECTION TO BE A SWEEP