Permit: T11CM00151

Parcel: 11205061A


Addresses:

1922 E HEDRICK DR

Inspection Status: Approved

Inspection History: PLUMBING - ROUGH, SOIL

Date Description Inspector Results Comments
06/20/2011 PLUMBING - ROUGH, SOIL Approved IVRS - Inspection :*
06/15/2011 PLUMBING - ROUGH, SOIL Not ready for Inspection IVRS - Inspection :*
1) CORRECT LEAK AND SLOPE
2) EXPOSE LOWER END
06/09/2011 PLUMBING - ROUGH, SOIL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) 4 X 3 RESTRICTION NOT ALLOWED 9" CLEARANCE REQUIRED
2) CLEANOUTS ARE REQUIRED AFTER 135 DEGREE CHANGE OF DIRECTION
3) PROVIDE PROPER ALLIGNMENT OF JOINTS
4) BACK PITCH IN SEVERAL LOCATIONS, EXPOSE TIE IN 5) CONTINUED NOT READY INSPECTIONS WILL RESULT IN REINSPECTION FEES
06/03/2011 PLUMBING - ROUGH, SOIL Not ready for Inspection IVRS - Inspection :*
1) PIPING IS TO BE SHADED-SO THAT IT IS LAID ON A FIRM BED
2) PIPING TO BE GRADED AT 2 PERCENT FOR IT'S ENTIRE LENGTH
04/07/2011 PLUMBING - ROUGH, SOIL Partial Approval IVRS - Inspection :*
1) SEE NOTES FROM 04/01/11
2) SEWER CONNECTION COVERED WITHOUT INSPECTION
3) OK FOR CONCRETE INSIDE BLDG
04/01/2011 PLUMBING - ROUGH, SOIL Partial Approval IVRS - Inspection :*
1) SOIL PIPE INSIDE BLDG WITH TEST ONE RISER OK
2) NEED TO SEE SEWER TIE IN AND VERIFY SLOPE
03/30/2011 PLUMBING - ROUGH, SOIL Not ready for Inspection IVRS - Inspection :*
1) NOT INSTALLED PER PLAN AND NO RED LINES ON SITE