Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit: T11CM00105

Parcel: 131131710


Addresses:

2425 S ROOK AV

Inspection Status: Cancelled

Inspection History: MECHANICAL - FINAL

Date Description Inspector Results Comments
01/21/2011 MECHANICAL - FINAL Cancelled IVRS - RI canceled
01/20/2011 MECHANICAL - FINAL Approved IVRS - Inspection :*
01/18/2011 MECHANICAL - FINAL Partial Approval IVRS - Inspection :*
1) SECURE THE ANGLE IRON STAND TO THE ROOF
2) PROVIDE THE REQUIRED GFI SERVICE RECEPT ON THE ROOF
3) PROVIDE A BUSHING IN THE ELECTRIC DISCONNECT
4) PROVIDE FUSES IN ELECTRIC DISCONNECT
5) PROVIDE R8 FLEX DUCT IN THE ATTIC AND AT PLENIUMS
6) TERMINATE CONDENSATE TO DIRT-NO HARD SURFACE
7) SUPPORT CONDENSATE DRAIN EVER 4'