Inspection History: MECHANICAL - HOODS
Permit Number - T11CM00103
Inspection Description - MECHANICAL - HOODS
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
06/30/2011 | MECHANICAL - HOODS | Approved | IVRS - Inspection :* 1) FINISH HINGE KIT AND GASKET FOR BAKER OVEN EXHAUST FAN-WILL CHECK AT FINAL |
|
06/29/2011 | MECHANICAL - HOODS | Not ready for Inspection | IVRS - Inspection :* | |
06/28/2011 | MECHANICAL - HOODS | Partial Approval | IVRS - Inspection :* 1) CHECKED 2ND LAYER OF GREASE DUCT FIRE WRAP 2) OK TO INSTALL DUCT |
|
06/27/2011 | MECHANICAL - HOODS | Partial Approval | IVRS - Inspection :* 1) 1ST LAYER FIRE WRAP OK, OK FOR NEXT LAYER, DO NOT DROP THRU CURB UNTIL 2ND LAYER HAS BEEN INSPECTED |
|
06/24/2011 | MECHANICAL - HOODS | Partial Approval | IVRS - Inspection :* 1) LIGHT TEST ON 9' GREASE DUCT OK, OK TO 1ST LAYER ENTIRE LENGTH, OK TO 2ND LAYER 1ST 30" |