Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - PROGRESS
Permit Number - T11CM00103
Inspection Description - PLUMBING - PROGRESS
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
08/03/2011 | PLUMBING - PROGRESS | Approved | IVRS - Inspection :* | |
08/02/2011 | PLUMBING - PROGRESS | Partial Approval | IVRS - Inspection :* | |
08/01/2011 | PLUMBING - PROGRESS | Not ready for Inspection | IVRS - Inspection :* | |
07/14/2011 | PLUMBING - PROGRESS | Partial Approval | IVRS - Inspection :* | |
06/29/2011 | PLUMBING - PROGRESS | Partial Approval | IVRS - Inspection :* | |
06/28/2011 | PLUMBING - PROGRESS | Denied | IVRS - Inspection : See detailed listing on site.| 999* |
|
06/27/2011 | PLUMBING - PROGRESS | Not ready for Inspection | IVRS - Inspection :* 1) YOU HAVE LEFT THESE OPEN PLUMBING VENTS IN THE FOOD PREP AREA OF THE BAKERY AND DELI IN THIS OPEN FOOD STORE, YOU HAVE BEEN ASKED AND WARNED NOT TO ALLOW THIS TO HAPPEN. CONCRETE SHALL PAY A REINSPECTION FEE WITHIN 5 DAYS 2) CAP OPEN PIPES, ALSO COMPLETE WORK IN THIS AREA AND CALL FOR AN INTERMEDIATE INSPECTION |
|
06/24/2011 | PLUMBING - PROGRESS | Partial Approval | IVRS - Inspection :* | |
06/22/2011 | PLUMBING - PROGRESS | Partial Approval | IVRS - Inspection :* | |
06/20/2011 | PLUMBING - PROGRESS | Not ready for Inspection | IVRS - Inspection :* | |
06/16/2011 | PLUMBING - PROGRESS | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) CUT PVC SHALL BE REAMED AND ? AS REQUIRED BY PVC INSTALLATION STANDARDS 2) REF SEC 310. WORKMANSHIP 3) JOINTS SHALL BE CUT SQUARE AND FULLY MADE UP |
|
06/14/2011 | PLUMBING - PROGRESS | Denied | IVRS - Inspection : See detailed listing on site.| 999* |
|
05/31/2011 | PLUMBING - PROGRESS | Not ready for Inspection | IVRS - Inspection :* | |
05/26/2011 | PLUMBING - PROGRESS | Partial Approval | IVRS - Inspection :* 1) COURTESY REINSPECTION FOR GEORGE |
|
05/26/2011 | PLUMBING - PROGRESS | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) REMOVE A TOILET FOR CLOSET FLANGE INSPECTION AND CALL FOR FINAL INSPECTION |
|
05/03/2011 | PLUMBING - PROGRESS | Not ready for Inspection | IVRS - Inspection :* CORRECT PIPE SIZING PER PLAN NOTES. 4-7 INSULATE AS SPECIFIED DWV TEST OK. SUPPORT AS REQUIRED |
|
04/28/2011 | PLUMBING - PROGRESS | Partial Approval | IVRS - Inspection :* | |
04/25/2011 | PLUMBING - PROGRESS | Denied | IVRS - Inspection : See detailed listing on site.| 999* |