Permit: T11CM00103

Parcel: 12201024J


Addresses:

3920 E GRANT RD


Inspection Status: Approved

Inspection History: PLUMBING - ROUGH, SOIL

Permit Number - T11CM00103

Inspection Description - PLUMBING - ROUGH, SOIL

Inspection Status - Approved

Date Description Inspector Results Comments
07/29/2011 PLUMBING - ROUGH, SOIL Approved IVRS - Inspection :*
07/11/2011 PLUMBING - ROUGH, SOIL Partial Approval IVRS - Inspection :*
07/08/2011 PLUMBING - ROUGH, SOIL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) FIXTURE TRAP AND TRAP ARM SHALL BE OF THE SAME SIZE
2) SWEEPS REQUIRED ON TRAP ARM CHANGE OF DIRECTION
3) READ THE NOTES !
07/07/2011 PLUMBING - ROUGH, SOIL Partial Approval IVRS - Inspection :*
1) 2 HAND SINKS TO ABOVE CEILING OK
2) COMPLETE VENTING AND SECURE
06/30/2011 PLUMBING - ROUGH, SOIL Partial Approval IVRS - Inspection :*
1) SOIL PIPING FROM BAKERY TO TIE IN OK. INSTALL FCO
2) AT PRODUCE: PROVIDE A FULL SIZED CLEANOUT, 4". PROVIDE A SEPERATE WASHER PIPE FOR 3 COMP SINK AND HAND SINK. HORIZONTAL WET VENTING NOT PERMITTED. INSTALL PER PLAN. INSTALL FS, ALSO FROM WRAPS
06/24/2011 PLUMBING - ROUGH, SOIL Partial Approval IVRS - Inspection :*
1) FS AT CASES
2) INTERCEPTOR INSTALL WITH TEST OK
06/22/2011 PLUMBING - ROUGH, SOIL Partial Approval IVRS - Inspection :*
1) EAST FREEZER CASE FS REPLACEMENT OK
2) BEVERAGE STATION AND BEVERAGE CASE FS OK
06/16/2011 PLUMBING - ROUGH, SOIL Not ready for Inspection IVRS - Inspection :*
1) CONTRACTOR CANCELLED
06/14/2011 PLUMBING - ROUGH, SOIL Partial Approval IVRS - Inspection :*
DELI AND BAKERY GW AND SANITARY SOIL PIPING ONLY,
2) WILL REQUIRE RETEST AT INTERMEDIATE SO THAT ALL JONTS ABOVE SLAB GET TESTED THRU DRAIN REQUIRES A WATER TEST
3) INSTALL FOAM WRAPS, FS AND FCO'S
06/01/2011 PLUMBING - ROUGH, SOIL Partial Approval IVRS - Inspection :*
1) FS AND CONNECTIONS AT COL B-7 OK
05/26/2011 PLUMBING - ROUGH, SOIL Partial Approval IVRS - Inspection :*
05/26/2011 PLUMBING - ROUGH, SOIL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) PROVIDE THE MINIMUM REQUIRED SLOPE
2) REMOVE WALL COVERINGS
05/25/2011 PLUMBING - ROUGH, SOIL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) VENT TAKE OFF IS REQUIRED TO BE ABOVE THE CENTER LINE OF THE PIPE
2) USE WYE AND 1/6" BEND
05/23/2011 PLUMBING - ROUGH, SOIL Not ready for Inspection IVRS - Inspection :*
05/02/2011 PLUMBING - ROUGH, SOIL Not ready for Inspection IVRS - Inspection :*
04/28/2011 PLUMBING - ROUGH, SOIL Partial Approval IVRS - Inspection :*
04/27/2011 PLUMBING - ROUGH, SOIL Partial Approval IVRS - Inspection :*PRESLAB IN TOILET RMS OK
04/25/2011 PLUMBING - ROUGH, SOIL Not ready for Inspection IVRS - Inspection :*