Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - ROUGH, SOIL
Permit Number - T11CM00103
Inspection Description - PLUMBING - ROUGH, SOIL
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
07/29/2011 | PLUMBING - ROUGH, SOIL | Approved | IVRS - Inspection :* | |
07/11/2011 | PLUMBING - ROUGH, SOIL | Partial Approval | IVRS - Inspection :* | |
07/08/2011 | PLUMBING - ROUGH, SOIL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) FIXTURE TRAP AND TRAP ARM SHALL BE OF THE SAME SIZE 2) SWEEPS REQUIRED ON TRAP ARM CHANGE OF DIRECTION 3) READ THE NOTES ! |
|
07/07/2011 | PLUMBING - ROUGH, SOIL | Partial Approval | IVRS - Inspection :* 1) 2 HAND SINKS TO ABOVE CEILING OK 2) COMPLETE VENTING AND SECURE |
|
06/30/2011 | PLUMBING - ROUGH, SOIL | Partial Approval | IVRS - Inspection :* 1) SOIL PIPING FROM BAKERY TO TIE IN OK. INSTALL FCO 2) AT PRODUCE: PROVIDE A FULL SIZED CLEANOUT, 4". PROVIDE A SEPERATE WASHER PIPE FOR 3 COMP SINK AND HAND SINK. HORIZONTAL WET VENTING NOT PERMITTED. INSTALL PER PLAN. INSTALL FS, ALSO FROM WRAPS |
|
06/24/2011 | PLUMBING - ROUGH, SOIL | Partial Approval | IVRS - Inspection :* 1) FS AT CASES 2) INTERCEPTOR INSTALL WITH TEST OK |
|
06/22/2011 | PLUMBING - ROUGH, SOIL | Partial Approval | IVRS - Inspection :* 1) EAST FREEZER CASE FS REPLACEMENT OK 2) BEVERAGE STATION AND BEVERAGE CASE FS OK |
|
06/16/2011 | PLUMBING - ROUGH, SOIL | Not ready for Inspection | IVRS - Inspection :* 1) CONTRACTOR CANCELLED |
|
06/14/2011 | PLUMBING - ROUGH, SOIL | Partial Approval | IVRS - Inspection :* DELI AND BAKERY GW AND SANITARY SOIL PIPING ONLY, 2) WILL REQUIRE RETEST AT INTERMEDIATE SO THAT ALL JONTS ABOVE SLAB GET TESTED THRU DRAIN REQUIRES A WATER TEST 3) INSTALL FOAM WRAPS, FS AND FCO'S |
|
06/01/2011 | PLUMBING - ROUGH, SOIL | Partial Approval | IVRS - Inspection :* 1) FS AND CONNECTIONS AT COL B-7 OK |
|
05/26/2011 | PLUMBING - ROUGH, SOIL | Partial Approval | IVRS - Inspection :* | |
05/26/2011 | PLUMBING - ROUGH, SOIL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) PROVIDE THE MINIMUM REQUIRED SLOPE 2) REMOVE WALL COVERINGS |
|
05/25/2011 | PLUMBING - ROUGH, SOIL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) VENT TAKE OFF IS REQUIRED TO BE ABOVE THE CENTER LINE OF THE PIPE 2) USE WYE AND 1/6" BEND |
|
05/23/2011 | PLUMBING - ROUGH, SOIL | Not ready for Inspection | IVRS - Inspection :* | |
05/02/2011 | PLUMBING - ROUGH, SOIL | Not ready for Inspection | IVRS - Inspection :* | |
04/28/2011 | PLUMBING - ROUGH, SOIL | Partial Approval | IVRS - Inspection :* | |
04/27/2011 | PLUMBING - ROUGH, SOIL | Partial Approval | IVRS - Inspection :*PRESLAB IN TOILET RMS OK | |
04/25/2011 | PLUMBING - ROUGH, SOIL | Not ready for Inspection | IVRS - Inspection :* |