Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
Permit Number - T11CM00018
Inspection Description - FRAMING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
09/17/2012 | FRAMING | Approved | IVRS - Inspection :* | |
03/20/2012 | FRAMING | Partial Approval | IVRS - Inspection :* 1) CLARIFY WEEP WITH ARCHITECT |
|
03/13/2012 | FRAMING | Denied | 1) FIRE BLOCKING REQUIRED AT ALL DROPPED CEILINGS. 2) ALL ELECTRICAL OUTLETS & J-BOXES MUST BE ACCESSIBLE (DON'T HIDE IN CEILING. 3) NO OPENINGS ARE ALLOWED INTO ELECTRICAL BOXES. IMPROPER USE OF MC CLAMPS ON ROMEX HAS LEFT HOLES 4) SECURE ROMEX WITHIN 12" OF OUTLETS. 5) DO NOT PUSH ROMEX AGAINST SHEATHING WHEN YOU INSULATE 6) WINDOWS HAVE NOT BEEN PROPERLY FLASHED 7) MISSING WEEP SCREED 8) SEAL ALL EXTERIOR FOAM PENETRATIONS WITH CAULK 9) PROVIDE MEANS OF REMOVING AIR HANDLER. IT MAY BE A LARGE ACCESS PANEL. |