Permit: T11BU01121

Parcel: 11521010E


Addresses:

1900 W SPEEDWAY BL


Inspection Status: Approved

Inspection History: GRADING - TIER REV

Permit Number - T11BU01121

Inspection Description - GRADING - TIER REV

Inspection Status - Approved

Date Description Inspector Results Comments
08/01/2013 GRADING - TIER REV Approved
02/27/2012 GRADING - TIER REV Continued Due to the bleed pipe within the bottom of each basin and the amount of ponding water left in the basin the final grading inspection will not be approved until an addendum to the Geotechnical Evaluation is provided with the as-built certification letter showing that percolation rates for the retention basins for 5-year threshold meets the drain down time maximum per DS Sec.10-01.3.5.1.