Permit: T11BU00999

Parcel: 10824011A


Addresses:

2450 E RIVER RD


Inspection Status: Approved

Inspection History: GRADING - INTERMEDIATE

Permit Number - T11BU00999

Inspection Description - GRADING - INTERMEDIATE

Inspection Status - Approved

Date Description Inspector Results Comments
03/06/2012 GRADING - INTERMEDIATE Approved
02/14/2012 GRADING - INTERMEDIATE Continued NO CHANGES OR CONCERNS AT THIS TIME. CONTRACTOR HAS NOT CALLED IN A FINAL INSPECTION
02/08/2012 GRADING - INTERMEDIATE Continued CONTRACTOR NEARING COMPLETION, NEED TO CALL IN FOR FINAL GRADING INSPECTION
12/14/2011 GRADING - INTERMEDIATE Continued NO SIGNIFICANT STORM WATER CONCERNS AT THIS TIME
09/12/2011 GRADING - INTERMEDIATE Continued 1) TOOK PICTURES OF STORM DRAIN PIPE FROM NE EXISTING CATCH BASIN TO NEW MANHOLE (TANSITION) AND NEW CATCH BASIN.
2) ENSURE PROPER MATERIAL, SLOPE, DIMENSION, AND COMPACTION OF PIPE AND TRENCH.
3) ENSURE ENDS OF ABONDON PIPE ARE GROUTED.
4) STORM DRAIN MANHOLE USE, STANDARD DETAIL 300, MANHOLE BASE 48" OR SMALLER.
09/07/2011 GRADING - INTERMEDIATE Continued 1) CONTRACTOR REMOVED SECTIONS OF EXISTING STORM DRAIN AND WILL RECONFIGURE TO TIE-IN 4" ROOF DRAINS FROM ADDITION TO EXISTING BLDG. TWO NEW CATCH BASIN WILL ALSO BE INSTALLED.
2) ONE PRE-CAST CATCH BASIN HAS BEEN SET, CALL FOR INSPECTION FOR PIPE TIE-IN AND PRIOR TO COVERING PIPE.
3) WORK IS BEING DONE PER THE APPROVED PLANS.
4) PLACE SEDIMENT PROTECTION AROUND EXISTING CATCH BASIN TO PREVENT SILTING-IN.