Inspection History Details
Inspection Status: Approved
Inspection History: GRADING - TIER REV
Permit Number - T11BU00117
Inspection Description - GRADING - TIER REV
Inspection Status - Approved
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 08/17/2011 | GRADING - TIER REV | Approved | ||
| 06/30/2011 | GRADING - TIER REV | Continued | GOT WITH SHANNON ABOUT CHECKING ON SWPPP CONTROLS AT END OF DAY | |
| 06/24/2011 | GRADING - TIER REV | Continued | CONTRACTOR NOT ON SITE NEED TO CLEAN UP CONCRETE FROM SITE. | |
| 05/24/2011 | GRADING - TIER REV | Continued | NO CONCERNS AT THIS TIME. | |
| 05/10/2011 | GRADING - TIER REV | Continued | NO CONCERNS AT THIS TIME. | |
| 04/28/2011 | GRADING - TIER REV | Continued | ||
| 04/21/2011 | GRADING - TIER REV | Continued | Plans do not have a sidewalk access from ROW to project. Discussed with Steve Shields sence this rpoject does not have parking or an office a ROW access was not required, nor was bike parking. |