Permit: T10PL02009

Parcel: 133500710


Addresses:

741 N HEARTHSIDE LN

Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Date Description Inspector Results Comments
01/14/2011 PLUMBING - FINAL Approved IVRS - Inspection :*
01/07/2011 PLUMBING - FINAL Partial Approval IVRS - Inspection :*
1) AN ATMOSPHERIC VAC BREAKER MAY NOT HAVE VALVES DOWN STREAM
2) OK TO COVER WALLS
01/05/2011 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
1) PROVIDE 18" IN WALL COPPER AT WATER HEATER
2) SECURE ALL ANGLE STOPS
3) PROVIDE CORRECT BACKFLOW PROTECTION FOR LANDSCAPE WITH VALVE DOWN STREAM OF BACKFLOW DEVICE
4) USE FITTING FOR CHANGE OF DIRECTION IN COPPER OR PROVIDE BEND WITH NO KINK AT RADIUS
01/03/2011 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
1) CONTRACTOR CANCELLED