Permit: T10PL01984

Parcel: 106062180


Addresses:

1032 W SIMMONS ST

Inspection Status: Partial Approval

Inspection History: PLUMBING - FINAL

Date Description Inspector Results Comments
12/30/2010 PLUMBING - FINAL Partial Approval IVRS - Inspection :*
1) GAS FLEX TO FURNACE IS UNDER SIZED
2) NEW WATER LINE REQUIRED 10' OF METALLIC PIPING TO SECURE AS GROUND
12/27/2010 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
1) INSTALL A (1 X 1/2 X 1/2) FULL SIZED
2) TEE AT APPLIANCE SPLIT
3) PIPE SOVS CLOSER TO THE FRONT FOR ACCESS-RETEST
4) EXTEND HARD PIPE TO OUTSIDE OF FURNACE FIRE BOX
5) INSTALL CORRECTLY SIZED FLEX
6) CHECK T & P FOR PROPER OPERATION AND PROVIDE A PETITION OF APPEAL FOR TERMINATION INTO PAN
7) NEW WATER LINE REQUIRES A PERMIT AND 10' OF COPPER FOR BONDING, NO TAPE ON PEX
8) NO MIXING OF GALV AND COPPER AND A HOSE BIB VACCUM BREAKER-PROTECT FROM CONCRETE