Inspection History Details
Inspection Status: Partial Approval
Inspection History: PLUMBING - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 12/30/2010 | PLUMBING - FINAL | Partial Approval | IVRS - Inspection :* 1) GAS FLEX TO FURNACE IS UNDER SIZED 2) NEW WATER LINE REQUIRED 10' OF METALLIC PIPING TO SECURE AS GROUND |
|
| 12/27/2010 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :* 1) INSTALL A (1 X 1/2 X 1/2) FULL SIZED 2) TEE AT APPLIANCE SPLIT 3) PIPE SOVS CLOSER TO THE FRONT FOR ACCESS-RETEST 4) EXTEND HARD PIPE TO OUTSIDE OF FURNACE FIRE BOX 5) INSTALL CORRECTLY SIZED FLEX 6) CHECK T & P FOR PROPER OPERATION AND PROVIDE A PETITION OF APPEAL FOR TERMINATION INTO PAN 7) NEW WATER LINE REQUIRES A PERMIT AND 10' OF COPPER FOR BONDING, NO TAPE ON PEX 8) NO MIXING OF GALV AND COPPER AND A HOSE BIB VACCUM BREAKER-PROTECT FROM CONCRETE |