Permit: T10PL01929

Parcel: 136081910


Addresses:

9421 E DEER TRAIL

Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Date Description Inspector Results Comments
12/16/2010 PLUMBING - FINAL Approved IVRS - Inspection :*
1) 15 PSI TEST IS OK
2) LEFT GAS CARD
12/15/2010 PLUMBING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) PROVIDE A SEDIMENT TRAP AT FURNACE
2) PROVIDE A NEW T & P RELIEF VALVE AND DO NOT HAVE FLEX COPPER IN THE DRAIN LINE
3) NEED TO SEE PIPING INSIDE THE TRENCH
4) PROVIDE A PERMIT FOR NEW A/C UNIT INSTALL
5) PROVIDE A ELECTRICAL BOND TO THE GAS PIPING
6) SYSTEM NOT HOLDING PRESSURE ON PRESSURE GAUGE, NOT WORKING PROPERLY