Permit: T10PL01925

Parcel: 132101870

Inspection Status: Approved

Inspection History: PLUMBING - GAS PRESSURE TEST

Date Description Inspector Results Comments
12/16/2010 PLUMBING - GAS PRESSURE TEST Approved IVRS - Inspection :*
1) PROVIDE CSA GAS APPROVED VALVE AT WATER HEATER AND STOVE
2) RUN T & P FOR WATER HEAT TO DAYLIGHT 6" TO 24" ABOVE GROUND 90 DEGREE DOWN
3) PROVIDE APPROVED FLUE VENTS FOR WATER HEATER AND FURNACE
4) CALL BACK FOR FINAL
12/15/2010 PLUMBING - GAS PRESSURE TEST Not ready for Inspection IVRS - Inspection :*
1) PLASTIC GAS MAIN TO BE MINIMUM 18" IN DEPTH TO TOP OF PIPE
2) FITTINGS IN TRENCH NEED TO BE COATED
3) COATED PIPE TO EXTEND MINIMUM 6" ABOVE GRADE