Permit: T10PL01711

Parcel: 11107257A


Addresses:

3150 E FLOWER ST

Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Date Description Inspector Results Comments
11/09/2010 PLUMBING - FINAL Approved IVRS - Inspection :*
11/08/2010 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
3150 E. FLOWER ST:
1) SEAL PIPE PENETRATION THRU ROOF TO WATER HEATER
2) HAVE APPROVED GAS VALVES AND FLEXES ON SITE
3) MAIN WATER HEATER VENT UP CORRECTLY AND PROVIDE FASTENERS AT EACH JOINT
4) PIPING TO BE SUPPORTED AND SECURED CORRECTLY ON ROOF
5) PROVIDE BONDING OF BLDG GAS PIPING
5152 E. FLOWER ST:
1) PROVIDE RIDGID NIPPLE THRU FURNACE APPLIANCE HOUSING
2) VERIFY APPOVED GAS SHUT OFF VAVLE AT FURNACE
3) HAVE APPROVED GAS VALVE AND FLEX ON SITE FOR WATER HEATER
4) SECURE GAS PIPING TO SUPPORTS ON ROOF AND SUPPORTS TO ROOF SURFACE
5) SEAL PIPE PENETRATION TO WATER HEATER AT ROOF
6) PROVIDE BONDING OF BLDG GAS SYSTEM
7) MAKE WATER HEATER VENT UP CORRECTLY AND PROVIDE FASTENERS AT EACH JOINT
8) RETEST BOTH SYSTEMS