Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 11/09/2010 | PLUMBING - FINAL | Approved | IVRS - Inspection :* | |
| 11/08/2010 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :* 3150 E. FLOWER ST: 1) SEAL PIPE PENETRATION THRU ROOF TO WATER HEATER 2) HAVE APPROVED GAS VALVES AND FLEXES ON SITE 3) MAIN WATER HEATER VENT UP CORRECTLY AND PROVIDE FASTENERS AT EACH JOINT 4) PIPING TO BE SUPPORTED AND SECURED CORRECTLY ON ROOF 5) PROVIDE BONDING OF BLDG GAS PIPING 5152 E. FLOWER ST: 1) PROVIDE RIDGID NIPPLE THRU FURNACE APPLIANCE HOUSING 2) VERIFY APPOVED GAS SHUT OFF VAVLE AT FURNACE 3) HAVE APPROVED GAS VALVE AND FLEX ON SITE FOR WATER HEATER 4) SECURE GAS PIPING TO SUPPORTS ON ROOF AND SUPPORTS TO ROOF SURFACE 5) SEAL PIPE PENETRATION TO WATER HEATER AT ROOF 6) PROVIDE BONDING OF BLDG GAS SYSTEM 7) MAKE WATER HEATER VENT UP CORRECTLY AND PROVIDE FASTENERS AT EACH JOINT 8) RETEST BOTH SYSTEMS |