Inspection Status: Approved
Inspection History: PLUMBING - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 11/05/2010 | PLUMBING - FINAL | Approved | IVRS - Inspection :* | |
| 11/04/2010 | PLUMBING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) WATER HEATER T & P DRAIN TO GRAVITY DRAIN TO DAYLIGHT TERMINATE 90 DEGREE DOWN 2) TEST GAS SYSTEM IN IT'S ENTIRETY 3) PROVIDE PROTECTION PLATES FOR INTERIOR GAS PIPING 4) PROVIDE APPROVED GAS SHUT OFF VALVE FOR STOVE 5) GAS SHUT OFF VALVE FOR ROOF TOP TO BE MAX 6' FROM APPLIANCE WITH CORRECT SUPPORT FOR BOX TOP PIPING 6) EXTEND DBL WALL WATER HEATER VENT THRU ROOF, PROVIDE COUNTER FLASHING AND TERMINATE WITH APPROVED VENT CAP 7) MAKE CORRECTIONS AND RETEST ENTIRE SYSTEM |