Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit: T10PL01582

Parcel: 135031420


Addresses:

6531 E CALLE CASTOR

Inspection Status: Denied

Inspection History: PLUMBING - GAS PRESSURE TEST

Date Description Inspector Results Comments
11/02/2010 PLUMBING - GAS PRESSURE TEST Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) UNDERGROUND GAS PIPING TO BE FACTORY COATED IF IRON PIPE WITH PIPE TAPE PRIMER ON ALL FITTINGS AND TOOL MARKS THEN WRAPPED WITH PIPE TAPE TO ACHIEVE 40 MIL THICKNESS OF WRAP
2) ALL GAS PIPING TO BE UNDER TEST AT TIME OF INSPECTION
3) THE TEST GAUGE YOUR USING IS DAMAGED AND NOT WORKING, PROVIDE FUNCTIONAL TEST GAUGE IN 1/10 POUND INCREMENTS
4) IF FIREPLACE LOG LIGHTER IS USED IT REQUIRES AN APPROVED GAS SHUT OFF VALVE OUTSIDE THE HEARTH OF FIREPLACE IN THE SAME ROOM WITHIN 6' OF FIREPLACE
5) PROVIDE APPROVED GAS SHUT OFF VALVE AT WATER HEATER
6) PROVIDE BONDING OF BLDG GAS SYSTEM
7) REMOVE THE TAPE AT SINLGE TO DBL WALL VENT CONNECTION OF WATER HEATER AND PROVIDE APPROVED DBL WALL VENT THRU ROOF AND CEILING WITH FLASHING AND APPROVED VENT CAP FOR WATER HEATER
8) THE 1/2" PIPE FROM THE EXTERIOR GOING UNDERGROUND IS UNDER SIZED TO FEED BOTH WATER HEATER AND FURNACE
9) INSTALL A GAS PIPING SYSTEM THAT MEETS THE BTU DEMAND ON ALL APPLIANCES
10) TEMPERATURE AND PRESSURE RELIEF DRAIN PIPE TO 90 DEGREE DOWN AT EXTERIOR
11) VENT FROM FURNACE TO BE APPROVED DBL WALL TERMINATING MINIMUM 3' ABOVE COOLER INTAKE WITHIN 10'
12) LIST MAY NOT BE COMPLETE
10/25/2010 PLUMBING - GAS PRESSURE TEST Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) PLEASE SCHEDULE AN INSPECTION WHEN SOMEONE WILL BE HOME