Permit: T10PL01552

Parcel: 125120620


Addresses:

3445 E 2ND ST

Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Date Description Inspector Results Comments
10/21/2010 PLUMBING - FINAL Approved IVRS - Inspection :*
1) CORRECTIONS MADE OK
2) OK FOR GAS
10/14/2010 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
1) CAP OLD GAS PIPING
2) REMOVE THE TAPE AT ALL VENT CONNECTIONS AND VERIFY FASTENERS
3) PROVIDE CORRECT VENT CONNECTION FROM SINGLE WALL TO DBL WALL IN WATER HEATER/FURNACE CLOSET
4) WATER HEATER TEMPERATURE AND PRESSURE RELIEF TO BE FUNCTIONAL AND GRAVITY DRAIN
5) GAS PIPING TO BE ARRANGED TO PROVIDE ACCESS TO REMOVE WATER HEATER WITHOUT DISASSEMBLY OF GAS PIPE
6) PROVIDE APPROVED FLASHING FOR PIPING PROPERLY SEALED WITH APPROVED ROOFING PRODUCTS TO MAKE WEATHER RESISTANT
7) PROVIDE APPROVED VENT CAP WITH FULL SIZE VENT PIPING (APPROVED) TO TERMINATE 3' ABOVE COMBUSTION AIR IN TAKE
8) PROVIDE BONDING OF BLDG GAS SYSTEM