Permit: T10PL01523

Parcel: 135051140


Addresses:

6445 E CALLE PEGASO

Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Date Description Inspector Results Comments
10/19/2010 PLUMBING - FINAL Approved IVRS - Inspection :*
10/15/2010 PLUMBING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
10/07/2010 PLUMBING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) PROVIDE A WORKING PRESSURE GAUGE
10/06/2010 PLUMBING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) PROVIDE YELLOW TRACER WIRE TERMINATED ABOVE GRADE AT BOTH ENDS
2) PROVIDE A 15 POUND PRESSURE GAUGE
3) PROVIDE MINIMUM 3 SCREWS IN ALL JOINTS OF VENT CONNECTORS
4) PROVIDE AN APPROVED SHUT OFF VALVE AT FURNACE
5) PROVIDE SEDIMENT TRAPS AT WATER HEATER AND FURNACE
6) PROVIDE TEST ON ENTIRE HOUSE
7) PROVIDE A BLDG SHUT OFF VALVE AT HOUSE