Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 10/12/2010 | PLUMBING - FINAL | Approved | IVRS - Inspection :* | |
| 10/07/2010 | PLUMBING - FINAL | Cancelled | IVRS - RI canceled | |
| 10/06/2010 | PLUMBING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) ALL GAS PIPING MUST BE UNDER TEST 2) EXTEND FURNACE AND WATER HEATER VENT MINIMUM 3' ABOVE COMBUSTION AIR INTAKE, REPLACE DAMAGED VENT CAP. USE ONLY DBL WALL PIPE FOR EXTENSION 3) PROVIDE SEDIMENT TRAPS AT FURNACE AND WATER HEATER 4) BE SURE ALL SHUT OFF VALVES ARE THE APPROVED TYPE 5) PROVIDE AN ELECTRIC BOND TO GAS PIPING 6) PROVIDE ACCESS TO ALL GAS APPLIANCES 7) LIST MAY NOT BE COMPLETE |