Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - GAS PRESSURE TEST
Permit Number - T10PL01458
Inspection Description - PLUMBING - GAS PRESSURE TEST
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
10/08/2010 | PLUMBING - GAS PRESSURE TEST | Approved | IVRS - Inspection :* 1) 15 PSI TEST IS OK 2) LEFT GAS CARD |
|
10/07/2010 | PLUMBING - GAS PRESSURE TEST | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) PROVIDE APPROVED COUPLINGS IN GAS LINE. UNIONS NOT ALLOWED IN CONCEALED SPACE 2) RETEST SYSTEM 3) EVERYTHING ELSE IS OK |
|