Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - FINAL
Permit Number - T10PL01418
Inspection Description - PLUMBING - FINAL
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
11/15/2010 | PLUMBING - FINAL | Approved | IVRS - Inspection :* 1) NO GAS CLEARANCE REQUIRED METER IS ON 2) CONTRACTOR TO MAKE FINAL CONNECTIONS TO METER AND FLEX TO BBQ AND PROVIDE SOAP TEST AT THAT TIME |
|
09/24/2010 | PLUMBING - FINAL | Partial Approval | IVRS - Inspection :* | |
09/21/2010 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :* #2030: 1) OK TO BURY, KEEP ALL ROCKS AND DEBRIS OFF OF PIPING 2) SECURE TRACER WIRE TO RISERS 3) ISOLATE/SLEEVE PIPING PASSING THRU MASONRY WALLS 4) RETEST AND RECALL FOR FINAL INSPECTION |