Permit: T10PL01414

Parcel: 140231450

Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Date Description Inspector Results Comments
02/24/2011 PLUMBING - FINAL Approved IVRS - Inspection :*
1) CORRECTIONS MADE OK
2) OK FOR GAS
09/15/2010 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
09/14/2010 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
1) PIPING TO BE 18" MINIMUM DEPTH
2) TEST TO BE ON ENTIRE SYSTEM
3) SUPPORT ALL PIPING
4) PROVIDE MINIMUM 40 MIL THICKNESS OF PIPE WRAP ON ALL UNDERGROUND TOOL MARKS AND FITTINGS
5) PROVIDE MINIMUM 3' ABOVE COOLER INTAKE WHEN WITHIN 10' OF COOLER INTAKE FOR WATER HEATER VENT TERMINATION WITH APPROVED VENT PIPING AND CAP