Permit: T10PL01303

Parcel: 136214160


Addresses:

7155 E 38TH ST

Inspection Status: Approved

Inspection History: PLUMBING - GAS PRESSURE TEST

Date Description Inspector Results Comments
10/28/2010 PLUMBING - GAS PRESSURE TEST Approved IVRS - Inspection :*
1) CORRECTIONS MADE OK
2) OK FOR GAS
09/14/2010 PLUMBING - GAS PRESSURE TEST Not ready for Inspection IVRS - Inspection :*
1) TEST TO HOLD WITH NO LOSS OF PRESSURE
2) VENT FROM WATER HEATER TO BE CONNECTED PROPERLY TO DRAFT HOOD AND SECURED TO INNER LINGER OF DBL WALL VENT PIPE. PROVIDE FASTENERS AT ALL JOINTS OF SINGLE WALL PIPING
3) T & P DRAIN TO GRAVITY DRAIN TO DAYLIGHT
4) PROVIDE COMBUSTION AIR FOR 35,00 BTU DEVICE
5) PROVIDE BONDING OF BLDG GAS PIPING
6) PROVIDE FIRM BEDDING FOR PIPING IN DITCH
7) PROVIDE APPROVED GAS VALVES AT APPLIANCES
8) FLEX CANNOT BE USED AS PIPING AT FURNACE. SUPPORT FURNACE PIPING
08/19/2010 PLUMBING - GAS PRESSURE TEST Cancelled CANCELLED PER HOMEOWNER PEDRO #240-7936
08/19/2010 PLUMBING - GAS PRESSURE TEST Not ready for Inspection IVRS - Inspection :*